Model
Branch Pipe for
Low Pressure Gas Line
Branch Pipe for
High/Low Pressure Gas Line
Branch Pipe for
Liquid Line
MW-NP142X2
ID 3/4
ID 1/2
ID 3/4
ID 7/8
ID 7/8
ID 5/8
ID 1/2
ID 5/8
ID 5/8
ID 3/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 1/2
ID 1/4
ID 3/8
ID 3/8
ID 1/2
ID 1/2
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 3/8
ID 1/4
ID 3/8
ID 3/8
ID 1/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
MW-NP282X2
ID 3/4
ID 1/2
ID 3/4
ID 7/8
ID 7/8
ID 5/8
ID 1/2
ID 5/8
ID 5/8
ID 3/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 3/4
ID 1/2
ID 3/4
ID 7/8
ID 7/8
ID 5/8
ID 1/2
ID 5/8
ID 5/8
ID 3/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 3/8
ID 1/4
ID 3/8
ID 3/8
ID 1/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
MW-NP452X2
ID 1/2
ID 5/8
ID 1-1/8
ID 1-1/8
ID 1
ID 3/4
ID 7/8
ID 7/8
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 3/4
ID 1/2
ID 3/4
ID 7/8
ID 7/8
ID 5/8
ID 1/2
ID 5/8
ID 5/8
ID 3/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 1/2
ID 1/4
ID 3/8
ID 3/8
ID 1/2
ID 1/2
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
MW-NP562X2
ID 1/2
ID 5/8
ID 1-1/8
ID 1-1/8
ID 1
ID 3/4
ID 7/8
ID 7/8
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 3/4
ID 1/2
ID 3/4
ID 7/8
ID 7/8
ID 5/8
ID 1/2
ID 5/8
ID 5/8
ID 3/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 3/8
ID 3/4
ID 5/8
ID 1/2
ID 3/8
ID 1/2
ID 5/8
ID 5/8
ID 7/8
ID 1/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
MW-NP692X2
ID 1/2
ID 5/8
ID 1-1/8
ID 1-1/8
ID 1
ID 3/4
ID 7/8
ID 7/8
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 1/2
ID 5/8
ID 1-1/8
ID 1-1/8
ID 1
ID 3/4
ID 7/8
ID 7/8
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 3/8
ID 3/4
ID 5/8
ID 1/2
ID 3/8
ID 1/2
ID 5/8
ID 5/8
ID 7/8
ID 1/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
MW-NP902X2
ID 1-1/2
ID 1-1/8
ID 1-1/4
ID 1-1/2
ID 1-3/8
ID 1-1/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 1/2
ID 5/8
ID 1-1/8
ID 1-1/8
ID 1
ID 3/4
ID 7/8
ID 7/8
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
ID 7/8
ID 3/4
ID 5/8
ID 3/8
ID 1/2
ID 5/8
ID 3/4
ID 7/8
ID 5/8
ID 1/2
ID 3/8
ID 1/4
(To Outdoor Unit)
(To Indoor Unit)
(To Main Piping)
Unit: inch, ID: Inner Diameter
Allow adequate space for elbow, angled, and irregular piping arrangements to compensate for expansion
and contraction brought on by temperature change.
4. Installation Work
4.1 Piping Connection Size
7KHHQGVRIWKHPXOWLNLWVDUH¿QLVKHGDVVKRZQLQWKHIROORZLQJ¿JXUHV&XWWKHHQGRIWKHSLSHWRFRUUHVSRQGWR
the pipe size.
6HUYLFH0DQXDO
INSTALLATION
Summary of Contents for YVAHP072B31S
Page 2: ......
Page 10: ...viii Service Manual ...
Page 16: ......
Page 17: ...Service Manual 1 1 INSTALLATION 1 Installation ...
Page 577: ...Service Manual 1 561 INSTALLATION 9 Touch Back to return to the Service Menu screen 9 ...
Page 920: ......
Page 921: ...Service Manual 2 1 OPERATION 2 Operation ...
Page 1315: ...Service Manual 3 1 TROUBLESHOOTING 3 Troubleshooting ...
Page 1461: ...Service Manual 4 1 MAINTENANCE 4 Maintenance ...
Page 1728: ......
Page 1729: ...Service Manual 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions ...
Page 1738: ...6 10 Service Manual FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A ft 3 l b ...
Page 1739: ...SERVICE PARTS LIST Service Manual 7 1 7 Service Parts List ...
Page 1795: ......
Page 1796: ... 2015 Johnson Controls Inc SM 15001 ...