Service Manual
1-679
INSTALLATION
2
Add, Change, and Delete Units
[Procedure]
(1) Current result acquisition in operation ratio function
(2) Stop operation ratio function
(3) Exit the management software
(4) Backup data
(5) Con
¿
rm connection and add, change, and delete units
(6) Restart the adapter
(7) Restart the management software
(8) Add and change remote controller groups
(9) Add and change groups
(10) Add and change blocks
(11) Add and change tenants
(12) Check controlling and monitoring settings
(13) Set of operation ratio function
(14) Restart operation ratio function
Ƒ
(1) Current result acquisition in operation ratio function
Calculate the operation ratio using current settings in cases where unit settings become modi
¿
ed or
changed.
(a) Click on [Ope.Ratio] > [Ope. ratio setting] > [Accumulated data setting].
(b) Click on [Acquire untaken data] to activate calculation.
NOTE:
Ɣ
Calculation might require some time, depending on the amount of data.
Ɣ
In cases of calculation information output, refer to
Service and Maintenance
8
Troubleshooting.
NOTICE:
For all other hours of the day, do not attempt to start this procedure within 15 minutes prior to the stroke of
the next hour. If the calculation period is set for a 24 hour span, do not perform this procedure within the
hours of midnight and 2:00am, local time. If the calculation period is set for a one hour time window, the
operation ratio calculation (ope. ratio cal function) will take effect for the following hour of operation.
NOTICE:
For all other hours of the day, do not attempt to start this procedure within 15 minutes prior to the stroke of
the next hour. If the calculation period is set for a 24 hour span, do not perform this procedure within the
hours of midnight and 2:00am, local time. If the calculation period is set for a one hour time window,
the operation ratio calculation (ope. ratio cal function) will take effect for the following hour of operation.
Summary of Contents for YVAHP072B31S
Page 2: ......
Page 10: ...viii Service Manual ...
Page 16: ......
Page 17: ...Service Manual 1 1 INSTALLATION 1 Installation ...
Page 577: ...Service Manual 1 561 INSTALLATION 9 Touch Back to return to the Service Menu screen 9 ...
Page 920: ......
Page 921: ...Service Manual 2 1 OPERATION 2 Operation ...
Page 1315: ...Service Manual 3 1 TROUBLESHOOTING 3 Troubleshooting ...
Page 1461: ...Service Manual 4 1 MAINTENANCE 4 Maintenance ...
Page 1728: ......
Page 1729: ...Service Manual 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions ...
Page 1738: ...6 10 Service Manual FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A ft 3 l b ...
Page 1739: ...SERVICE PARTS LIST Service Manual 7 1 7 Service Parts List ...
Page 1795: ......
Page 1796: ... 2015 Johnson Controls Inc SM 15001 ...