Refrigerant Precautions
7RUHGXFHWKHULVNRIVHULRXVLQMXU\RUGHDWKWKHIROORZLQJUHIULJHUDQW
precautions must be followed.
Ɣ
$VRULJLQDOO\PDQXIDFWXUHGWKLVXQLWFRQWDLQVUHIULJHUDQWLQVWDOOHGE\-RKQVRQ&RQWUROV-RKQVRQ
&RQWUROVXVHVRQO\UHIULJHUDQWVWKDWKDYHEHHQDSSURYHGIRUXVHLQWKHXQLW¶VLQWHQGHGKRPHFRXQWU\
RUPDUNHW-RKQVRQ&RQWUROVGLVWULEXWRUVVLPLODUO\DUHRQO\DXWKRUL]HGWRSURYLGHUHIULJHUDQWVWKDW
have been approved for use in the countries or markets they serve. The refrigerant used in this unit
LVLGHQWL¿HGRQWKHXQLW¶VIDFHSODWHDQGRULQWKHDVVRFLDWHGPDQXDOV$Q\DGGLWLRQVRIUHIULJHUDQWLQWR
WKLVXQLWPXVWFRPSO\ZLWKWKHFRXQWU\¶VUHTXLUHPHQWVZLWKUHJDUGWRUHIULJHUDQWXVHDQGVKRXOGEH
REWDLQHGIURP-RKQVRQ&RQWUROVGLVWULEXWRUV8VHRIDQ\QRQDSSURYHGUHIULJHUDQWVXEVWLWXWHVZLOOYRLG
the warranty and will increase the potential risk of injury or death.
Ɣ
,ILQVWDOOHGLQDVPDOOURRPWDNHPHDVXUHVWRSUHYHQWWKHUHIULJHUDQWIURPH[FHHGLQJWKHPD[LPXP
allowable concentration in the event that refrigerant gases should escape. Refrigerant gases can
cause asphyxiation (0.026 lbs/ft
3
(0.42 kg/m
3
) based on ISO 5149 for R410A). Consult with your
distributor for countermeasures (ventilation system and so on). If refrigerant gas has leaked during the
LQVWDOODWLRQZRUNYHQWLODWHWKHURRPLPPHGLDWHO\
Ɣ
%HIRUHLQVWDOODWLRQLVFRPSOHWHPDNHVXUHWKDWWKHUHIULJHUDQWOHDNWHVWKDVEHHQSHUIRUPHG,I
UHIULJHUDQWJDVHVHVFDSHLQWRWKHDLUWXUQ2))WKHPDLQVZLWFKH[WLQJXLVKDQ\RSHQÀDPHVDQG
contact your service contractor. Refrigerant (Fluorocarbon) for this unit is odorless. If the refrigerant
VKRXOGOHDNDQGFRPHLQWRFRQWDFWZLWKRSHQÀDPHVWR[LFJDVFRXOGEHJHQHUDWHG$OVREHFDXVHWKH
ÀXRURFDUERQVDUHKHDYLHUWKDQDLUWKH\VHWWOHWRWKHÀRRUZKLFKFRXOGFDXVHDVSK\[LDWLRQ
Ɣ
:KHQLQVWDOOLQJWKHXQLWDQGFRQQHFWLQJUHIULJHUDQWSLSLQJNHHSDOOSLSLQJUXQVDVVKRUWDVSRVVLEOH
and make sure to securely connect the refrigerant piping before the compressor starts operating. If
WKHUHIULJHUDQWSLSLQJLVQRWFRQQHFWHGDQGWKHFRPSUHVVRUDFWLYDWHVZLWKWKHVWRSYDOYHRSHQHGWKH
UHIULJHUDQWF\FOHZLOOEHFRPHVXEMHFWHGWRH[WUHPHO\KLJKSUHVVXUHZKLFKFDQFDXVHDQH[SORVLRQRU¿UH
Ɣ
7LJKWHQWKHÀDUHQXWZLWKDWRUTXHZUHQFKLQWKHVSHFL¿HGPDQQHU'RQRWDSSO\H[FHVVLYHIRUFHWRWKH
ÀDUHQXWZKHQWLJKWHQLQJ,I\RXGRWKHÀDUHQXWFDQFUDFNDQGUHIULJHUDQWOHDNDJHPD\RFFXU
Ɣ
A compressor/unit comprises a pressurized system. Never loosen threaded joints while the system is
under pressure and never open pressurized system parts.
Ɣ
:KHQPDLQWDLQLQJUHORFDWLQJDQGGLVSRVLQJRIWKHXQLWGLVPDQWOHWKHUHIULJHUDQWSLSLQJDIWHUWKH
compressor stops.
Electrical Precautions
7DNHWKHIROORZLQJSUHFDXWLRQVWRUHGXFHWKHULVNRIHOHFWULFVKRFN¿UHRU
explosion resulting in serious injury or death.
Ɣ
Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and
these instructions when wiring. Improper connections and inadequate grounding can cause serious
injury or death.
Ɣ
%HIRUHVHUYLFLQJRSHQDQGWDJDOOGLVFRQQHFWVZLWFKHV1HYHUDVVXPHHOHFWULFDOSRZHULV
disconnected. Check with meter and equipment.
Ɣ
Only use electrical protection equipment and tools suited for this installation.
Ɣ
8VHVSHFL¿HGFDEOHVEHWZHHQXQLWV
Ɣ
Communication cable shall be a minimum of AWG18 (0.82mm
2
&RQGXFWRU6WUDQGHG&RSSHU
Shielded cable must be considered for applications and routing in areas of high EMI and other
sources of potentially excessive electrical noise to reduce the potential for communication errors.
:KHQVKLHOGHGFDEOHLVDSSOLHGSURSHUERQGLQJDQGWHUPLQDWLRQRIWKHFDEOHVKLHOGLVUHTXLUHGDVSHU
-RKQVRQ&RQWUROVJXLGHOLQHV3OHQXPDQGULVHUUDWLQJVIRUFRPPXQLFDWLRQFDEOHVPXVWEHFRQVLGHUHG
per application and local code requirements.
Ɣ
8VHDQH[FOXVLYHSRZHUVXSSO\IRUWKHDLUFRQGLWLRQHUDWWKHXQLW¶VUDWHGYROWDJH
Ɣ
%HVXUHWRLQVWDOOFLUFXLWEUHDNHUVJURXQGIDXOWLQWHUUXSWHULVRODWLQJVZLWFKPROGHGFDVHFLUFXLW
EUHDNHUDQGVRRQZLWKWKHVSHFL¿HGFDSDFLW\(QVXUHWKDWWKHZLULQJWHUPLQDOVDUHWLJKWHQHG
VHFXUHO\WRUHFRPPHQGHGWRUTXHVSHFL¿FDWLRQV,IDFLUFXLWEUHDNHURUIXVHLVIUHTXHQWO\DFWLYDWHG
shut down the system and contact your service contractor.
Summary of Contents for YVAHP072B31S
Page 2: ......
Page 10: ...viii Service Manual ...
Page 16: ......
Page 17: ...Service Manual 1 1 INSTALLATION 1 Installation ...
Page 577: ...Service Manual 1 561 INSTALLATION 9 Touch Back to return to the Service Menu screen 9 ...
Page 920: ......
Page 921: ...Service Manual 2 1 OPERATION 2 Operation ...
Page 1315: ...Service Manual 3 1 TROUBLESHOOTING 3 Troubleshooting ...
Page 1461: ...Service Manual 4 1 MAINTENANCE 4 Maintenance ...
Page 1728: ......
Page 1729: ...Service Manual 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions ...
Page 1738: ...6 10 Service Manual FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A ft 3 l b ...
Page 1739: ...SERVICE PARTS LIST Service Manual 7 1 7 Service Parts List ...
Page 1795: ......
Page 1796: ... 2015 Johnson Controls Inc SM 15001 ...