1-370
Service Manual
INSTALLATION
No.
Items
Optional Function
Individual
Setting
Setting
Condition
Contents
Setting
68
H1
Not Prepared
-
-
Not Used (Use as 00 conditions)
69
H2
Indication of Hot Start
×
00
01
Indication
No Indication
70
H3
Not Prepared
-
-
Not Used (Use as 00 conditions)
71
H4
Not Prepared
-
-
Not Used (Use as 00 conditions)
72
H5
Not Prepared
-
-
Not Used (Use as 00 conditions)
73
J1
Temperature Indication (*9)
×
00
01
Not Available
Available
74
J2
Not Prepared
-
-
Not Used
75
J3
Run Indicator Color
×
00
01
Green
Red
76
J4
Not Prepared
-
-
Not Used (Use as 00 conditions)
77
J5
Not Prepared
-
-
Not Used (Use as 00 conditions)
78
J6
Not Prepared
-
-
Not Used (Use as 00 conditions)
79
J7
Not Prepared
-
-
Not Used (Use as 00 conditions)
80
J8
Eco-operation (*10)
×
00
01
Not Available
Available
81
J9
Not Prepared
-
-
Not Used (Use as 00 conditions)
82
JA
Not Prepared
-
-
Not Used (Use as 00 conditions)
83
Jb
Not Prepared
-
-
Not Used (Use as 00 conditions)
84
K1
Not Prepared
-
-
Not Used (Use as 00 conditions)
85
K2
Not Prepared
-
-
Not Used (Use as 00 conditions)
86
K3
Not Prepared
-
-
Not Used (Use as 00 conditions)
87
K4
Not Prepared
-
-
Not Used (Use as 00 conditions)
88
K5
Motion Sensor Detection Level
×
00
01
02
Standard
High
Low
89
K6
Selecting Operation Mode when
Selecting Thermistor of Controller and
Remote Sensor
ż
00
01
02
03
ALL
COOL
HEAT
ALL
90
K7
Radiation Temperature Sensor
Calibration
ż
00
01
02
03
Normal
Upper
Lower
Normal
91
K8
Moisture Control and Prevention
ż
00
01
Not Available
Available
92
K9,KA Not Prepared
-
-
Not Used
93
L1
Setting Position of Motion Sensor
ż
00
01
02
03
A
B
-
D
94
L2
Not Prepared
-
-
Not Used
95
L3
Louver in Power Saving
ż
00
01
02
03
LOW
MED
HIGH
OFF
96
L4
Fan Speed Up when Power Saving
Thermo OFF
ż
00
01
Not Available
Available
97
L5
Louver Availability during Power Saving
ż
00
01
Not Available
Available
98
L6~Lb Not Prepared
-
-
Not Used
99
P1
Setting Unit Temperature Setpoint
×
00
01
0.5
o
C
1
o
C
100
P2
Not Prepared
-
-
Not Used
Summary of Contents for YVAHP072B31S
Page 2: ......
Page 10: ...viii Service Manual ...
Page 16: ......
Page 17: ...Service Manual 1 1 INSTALLATION 1 Installation ...
Page 577: ...Service Manual 1 561 INSTALLATION 9 Touch Back to return to the Service Menu screen 9 ...
Page 920: ......
Page 921: ...Service Manual 2 1 OPERATION 2 Operation ...
Page 1315: ...Service Manual 3 1 TROUBLESHOOTING 3 Troubleshooting ...
Page 1461: ...Service Manual 4 1 MAINTENANCE 4 Maintenance ...
Page 1728: ......
Page 1729: ...Service Manual 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions ...
Page 1738: ...6 10 Service Manual FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A ft 3 l b ...
Page 1739: ...SERVICE PARTS LIST Service Manual 7 1 7 Service Parts List ...
Page 1795: ......
Page 1796: ... 2015 Johnson Controls Inc SM 15001 ...