pnt0-17
Device fault...Reset initiated!
Explanation: The SunSoft Solaris driver has been reset due to a device
fault.
Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters
are present or replace the Ethernet adapter that fails to respond. If the
problem persists, go to “General checkout” on page 6 to run the diagnostic
programs.
pnt0-19
IRQ found for PCnet hardware does not match space.c
(or pnt.conf)!
Explanation: This is a warning message referring to the interrupt request
(IRQ) that the SunSoft Solaris driver found in the system.
Action: Ignore this message if you are sure that this is what you want to do.
Otherwise, run the NETCONFIG program to match the hardware settings.
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that
was found, conflicts with other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-21
add_intr_handler failed! Out of range interrupt number.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that
was found, conflicts with other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-22
add_intr_handler failed! Out of range IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that
was found, conflicts with other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-23
add_intr_handler failed! Vector already occupied.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that
was found, conflicts with other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-24
add_intr_handler failed! Vector already shared at
different IPL.
Explanation: The interrupt request (IRQ) that was specified, or the IRQ that
was found, conflicts with other devices in the server.
Action: Modify your hardware settings.
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-26
The DMA number is not necessary for PCI device.
Explanation: The IBM Netfinity 10/100 Fault Tolerant Adapter does not
require a DMA setting.
Action: Edit the SPACE.C file to delete the DMA parameter.
pnt0-29
The IRQ number is already in use.
Explanation: The specified I/O address is already in use.
Action: Run the NETCONFIG program to modify your hardware settings.
pnt0-31
I/O address is not necessary for the PCI device.
Explanation: The I/O address specified is not required.
Action: Remove the assigned I/O address specified for the Ethernet
controller.
222
Netfinity Server HMM
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...