Diagnostics panel LEDs:
The following illustration
shows the LEDs on the diagnostics panel inside the
server. See “Light path diagnostics” on page 13 for
information on identifying problems using these LEDs.
AC Power
LED
DC Power
LED
Description and action
On
On
The power supply is on and
operating correctly.
On
Off
There is a DC power problem.
Possible causes:
1. The Power Control button
on the front of the server is
in the Off position.
Action: Press the Power
Control button to start the
server.
2. The power supply has
failed.
Action: Replace the
power supply.
Off
Off
There is an AC power problem.
Possible causes:
1. There is no AC power to
the power supply.
Actions: Verify that:
The power cord is
properly connected to
the server.
The power outlet
functions properly.
2. The power supply has
failed.
Action: Replace the
power supply.
If the problem persists, go to
“Undetermined problems” on
page 215
196
Netfinity Server HMM
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...