Error Code/Symptom
FRU/Action
1304
(Cable to Diagnostic LED
panel not detected.
1. Cable
1600, 1601
(The system is able to
communicate to the Service
Processor, but the Service
Processor failed to respond
at the start of POST.)
Do the following before
replacing a FRU:
1. Remove the ac power
to the system, wait 20
seconds; then,
re-connect the ac
power. Wait 30
seconds; then,
power-on the system.
2. Flash update the
Service Processor.
3. Check the SP reset
jumper, if fitted.
1. System Board
1762
(Fixed Disk Configuration
error)
1. Fixed Disk Cables
2. Run
Configuration/Setup
3. Fixed Disk Adapter, if
fitted
4. Fixed Disk Drive
5. System Board
178X
(Fixed Disk error)
1. Fixed Disk Cables
2. Run Diagnostics
3. Fixed Disk Adapter, if
fitted
4. Fixed Disk Drive
5. System Board
1800
(No more hardware interrupt
available for PCI adapter)
1. Run
Configuration/Setup
2. Failing Adapter
3. System Board
1801
(No room for PCI option
ROM)
1. Run
Configuration/Setup
2. Failing Adapter
3. System Board
1802
(No more I/O space
available for PCI adapter)
1. Run
Configuration/Setup
2. Failing Adapter
3. System Board
1803
(No more memory (above
1MB for PCI adapter)
1. Run
Configuration/Setup
2. Failing Adapter
3. System Board
212
Netfinity Server HMM
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...