Error Code/Symptom
FRU/Action
175
(Hardware error)
1. Processor Board
2. System Board
176
(Computer cover or cable
cover was removed without
a key being used)
1. Run
Configuration/Setup
2. System Board
177, 178
(Security hardware error)
1. Run
Configuration/Setup
2. Remove AC power and
reboot.
3. System Board
184
(Security hardware error)
1. Run
Configuration/Setup
2. Remove AC power and
reboot.
3. System Board
185
(Security hardware error)
1. Run
Configuration/Setup
2. Remove AC power and
reboot.
3. System Board
186
1. Run
Configuration/Setup
2. System Board
187
(Security hardware error)
1. Run
Configuration/Setup
2. Remove AC power and
reboot.
3. System Board
188
(Security hardware error)
1. Run
Configuration/Setup
2. Remove AC power and
reboot.
3. System Board
189
(An attempt was made to
access the server with
invalid passwords)
1. Run
Configuration/Setup,
enter the
administrator
password
201
(Memory test error)
1. DIMM
2. Processor Board
3. System Board
229
(Cache error)
1. Processor
2. Optional Processor
(if installed)
3. Processor Board
262
(DRAM configuration error)
1. Run
Configuration/Setup
2. Battery
3. System Board
210
Netfinity Server HMM
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...