Error Code/Symptom
FRU/Action
035-253-199
(RAID adapter initialization
failure)
1. ServeRAID Adapter in
PCI slot 1 is not
configured properly.
Obtain the basic and
extended configuration
status and refer to the
ServeRAID HMM for
more information.
035-XXX-1NN
(Check system error log
before replacing a FRU.
NN = SCSI ID or fixed disk.)
1. Fixed disk with SCSI
ID NN on RAID
adapter in PCI slot 1
035-XXX-299
(Failed RAID test on PCI
slot 2. Check system error
log before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-253-299
(RAID adapter initialization
failure)
1. ServeRAID Adapter in
PCI slot 2 is not
configured properly.
Obtain the basic and
extended configuration
status and refer to the
ServeRAID HMM for
more information.
035-XXX-2NN
(Check system error log
before replacing a FRU.
NN = SCSI ID or fixed disk.)
1. Fixed disk with SCSI
ID NN on RAID
adapter in PCI slot 2
035-XXX-399
(Failed RAID test on PCI
slot 3. Check system error
log before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-253-399
(RAID adapter initialization
failure)
1. ServeRAID Adapter in
PCI slot 3 is not
configured properly.
Obtain the basic and
extended configuration
status and refer to the
ServeRAID HMM for
more information.
035-XXX-3NN
(Check system error log
before replacing a FRU.
NN = SCSI ID or fixed disk.)
1. Fixed disk with SCSI
ID NN on RAID
adapter in PCI slot 3
035-XXX-499
(Failed RAID test on PCI
slot 4. Check system error
log before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
Netfinity 5600 - Type 8664
203
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...