Error Code/Symptom
FRU/Action
289
(DIMM has been disabled
the user or system)
1. Run
Configuration/Setup,
if disabled by user
2. Ensure if a DIMM was
added/changed that
the power was
disconnected.
3. Disabled DIMM, if not
disabled by user.
4. Processor Board
301
(Keyboard or keyboard
controller error)
1. Keyboard
2. System Board
303
(Keyboard controller error)
1. Keyboard
2. System Board
602
(Invalid diskette boot record)
1. Diskette
2. Cable
3. Diskette Drive
604
(Diskette drive error)
1. Run
Configuration/Setup
and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
605
(Unlock failure)
1. Diskette Drive
2. Drive Cable
3. System Board
662
(Diskette drive configuration
error)
1. Run
Configuration/Setup
and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
962
(Parallel port error)
1. Disconnect external
cable on parallel port.
2. Run
Configuration/Setup
3. System Board
11XX
(System board serial port 1
or 2 error)
1. Disconnect external
cable on serial port.
2. Run
Configuration/Setup
3. System Board
1301
(Cable to Information LED
panel not detected.
1. Cable
1302
(Cable to Power and Reset
pushbuttons not detected.
1. Cable
1303
(I2C cable to Power
Backplane not detected)
1. Cable
Netfinity 5600 - Type 8664
211
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...