5. Highlight one of the adapters that will be in the
redundant pair and then click the Properties... button.
6. Check the Grouping box. This will show the possible
combinations for redundant pairs.
7. Select the adapter pair you want and then select OK.
Note that the integrated Ethernet controller is located
at PCI bus A, slot 2 (bus 0, slot 2).
Two options are available for recovering from a
failover condition. The options are determined by the
Enable for DMI / Hot Swap Support checkbox. If the
IBM Netfinity Hot Plug PCI for Windows NT Server
4.0 package is installed, this checkbox will appear at
the bottom of the Adapter Properties panel. If you do
not have the IBM Netfinity Hot Plug PCI for Windows
NT Server 4.0 package installed on the server, you
will not see the Enable for DMI / Hot Swap Support
checkbox.
If the Enable for DMI / Hot Swap Support checkbox is
not checked or is not present, traffic will automatically
switch back to the primary adapter when the primary
link status is restored. In this mode, the adapter
cannot be hot-swapped. Users with the IBM Netfinity
Hot Plug PCI for Windows NT Server 4.0 package
installed should check the Enable for DMI / Hot Swap
Support checkbox.
If the Enable for DMI / Hot Swap Support checkbox
is checked, traffic will remain on the secondary
adapter until the user directs it to return to the primary
adapter. This can be done after the hot-swap
replacement of the primary adapter or by using the
DMI interface.
8. Select Close to exit from the Network setup.
When you restart the server, the failover function will
be in effect.
If a failover occurs, a message is written to the NT Event
Viewer log. In addition, if the Enable for DMI / Hot Swap
Support checkbox is checked, a DMI alert will also be
generated.
IntraNetWare
1. Add the redundant NIC adapter according to the
instructions provided with the adapter and in “Working
with adapters” on page 107.
2. Load the device driver by using the following
command:
LOAD
d
:\
path
\
PCNTNW.LAN PRIMARY=
x
SECONDARY=
y
where
d and path are the drive and path where the
driver is located, and
x and y are the PCI slot
numbers where the redundant pair is located.
Netfinity 5600 - Type 8664
49
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...