Error Code/Symptom
FRU/Action
180-XXX-003
(Failed System Board LED
test)
1. System Board
180-XXX-004
(Failed Processor Board
LED test)
1. Processor Board
2. System Board
180-XXX-005
(Failed SCSI Backplane
LED test)
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
201-XXX-001
(Failed Memory test)
1. DIMM Location J4
201-XXX-002
(Failed Memory test)
1. DIMM Location J3
201-XXX-003
(Failed Memory test)
1. DIMM Location J2
201-XXX-004
(Failed Memory test)
1. DIMM Location J1
201-XXX-999
(Multiple DIMM failure, see
error text.)
1. See error text for
failing DIMMs
202-XXX-001
(Failed System Cache test)
1. Microprocessor
202-XXX-002
(Failed System Cache test
on Optional Microprocessor)
1. Optional
Microprocessor
206-XXX-000
(Failed Diskette Drive test)
1. Diskette Drive cable
2. Diskette Drive
215-XXX-000
(Failed IDE CD-ROM test)
1. CD-ROM Drive
Cables
2. CD-ROM Drive
3. System Board
217-XXX-000
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical drive.
1. Fixed Disk 1
217-XXX-001
(Failed BIOS Fixed Disk
test)
Note
If RAID is configured,
the fixed disk number
refers to the RAID
logical drive.
1. Fixed Disk 2
Netfinity 5600 - Type 8664
205
Summary of Contents for 866441Y - Netfinity 5600 - 8664
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 244: ...236 Netfinity Server HMM...
Page 245: ...Related service information 237...
Page 246: ...238 Netfinity Server HMM...
Page 247: ...Related service information 239...
Page 258: ...250 Netfinity Server HMM...
Page 259: ...Related service information 251...
Page 275: ......
Page 276: ...IBM Part Number 09N1595 Printed in U S A S 9N 1595...