HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide
59
FlowErrors 0 TotalOfflineSeq 1
FReject 0 TotalRxFrames 4432
InvalidCRC 0 TotalRxWords 300995
InvalidDestAddr 0 TotalTxFrames 28640
LIP_AL_PD_AL_PS 0 TotalTxWords 483225
LIP_F7_AL_PS 0 TxLinkResets 0
LIP_F7_F7 2 TxOfflineSeq 1
LIP_F8_AL_PS 0
Port threshold alarm configuration parameters
To display the port threshold alarm parameters, enter the
show config threshold
command. These
parameters determine the error thresholds at which the switch issues alarms. See
Table 37
for descriptions
of these parameters.
SN6000 FC Switch #> show config threshold
Configuration Name: default
------------
Threshold Configuration Information
-----------------------------------
ThresholdMonitoringEnabled False
CRCErrorsMonitoringEnabled True
RisingTrigger 25
FallingTrigger 1
SampleWindow 10
DecodeErrorsMonitoringEnabled True
RisingTrigger 25
FallingTrigger 0
SampleWindow 10
ISLMonitoringEnabled True
RisingTrigger 2
FallingTrigger 0
SampleWindow 10
LoginMonitoringEnabled True
RisingTrigger 5
FallingTrigger 1
SampleWindow 10
LogoutMonitoringEnabled True
RisingTrigger 5
FallingTrigger 1
SampleWindow 10
LOSMonitoringEnabled True
RisingTrigger 100
FallingTrigger 5
SampleWindow 10
Summary of Contents for StorageWorks SN6000
Page 16: ...16 Command Line Interface Usage ...
Page 20: ...20 User Account Configuration ...
Page 34: ...34 Network Configuration ...
Page 82: ...82 Zoning Configuration ...
Page 86: ...86 Connection Security Configuration ...
Page 96: ...96 Device Security Configuration ...
Page 100: ...100 RADIUS Server Configuration ...
Page 124: ...124 Simple Network Management Protocol Configuration ...
Page 318: ...318 Command Reference ...
Page 330: ...330 Index ...