HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 117
12 Simple Network Management Protocol Configuration
The Simple Network Management Protocol (SNMP) provides for the management of the switch through
third-party applications that use SNMP. Security consists of a
ReadCommunity
string and a
WriteCommunity
string that serve as passwords that control read and write access to the switch. These
strings are set at the factory to well-known defaults and should be changed if SNMP is to be enabled. The
switch supports SNMP version 3 in the CLI, which is disabled by default.
Managing the SNMP service
You control the SNMP service
SNMPEnabled
parameters through the
set setup snmp
or
set setup services
commands. See ”
Modifying the SNMP configuration
” (page 119).
To enable SNMP, enter the
set setup services
command, as shown in the following example:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #> set setup services
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
PLEASE NOTE:
-----------
* Further configuration may be required after enabling a service.
* If services are disabled, the connection to the switch may be lost.
* When enabling SSL, please verify that the date/time settings
on this switch and the workstation from where the SSL connection
will be started match, and then a new certificate may need to be
created to ensure a secure connection to this switch.
TelnetEnabled (True / False) [True ]
SSHEnabled (True / False) [False]
GUIMgmtEnabled (True / False) [True ]
SSLEnabled (True / False) [False]
EmbeddedGUIEnabled (True / False) [True ]
SNMPEnabled (True / False) [True ]
NTPEnabled (True / False) [False]
CIMEnabled (True / False) [False]
FTPEnabled (True / False) [True ]
MgmtServerEnabled (True / False) [True ]
CallHomeEnabled (True / False) [True ]
Do you want to save and activate this services setup? (y/n): [n]
You can display the
SNMPEnabled
parameters using the
show setup snmp
or
show setup services
commands.
Summary of Contents for StorageWorks SN6000
Page 16: ...16 Command Line Interface Usage ...
Page 20: ...20 User Account Configuration ...
Page 34: ...34 Network Configuration ...
Page 82: ...82 Zoning Configuration ...
Page 86: ...86 Connection Security Configuration ...
Page 96: ...96 Device Security Configuration ...
Page 100: ...100 RADIUS Server Configuration ...
Page 124: ...124 Simple Network Management Protocol Configuration ...
Page 318: ...318 Command Reference ...
Page 330: ...330 Index ...