HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide 295
StopOnError
Stops the test when an error occurs (
True
). Otherwise, the test continues to
completion.
LoopForever
Restarts the test after completion and continues until you cancel it (
True
).
Otherwise, the test ends normally after completion.
Table 72
Switch test parameters (continued)
Parameter
Description
Examples
The following example performs an offline internal test on a switch:
SN6000 FC Switch #> admin start
SN6000 FC Switch (admin) #>set switch state diagnostics
SN6000 FC Switch (admin) #> test switch offline internal
A list of attributes with formatting and current values will follow. Enter a
new value or simply press the ENTER key to accept the default value. If you
wish to terminate this process before reaching the end of the list press 'q'
or 'Q' and the ENTER key to do so.
LoopCount (decimal value, 1-4294967295) [100 ]
FrameSize (decimal value, 40-2148) [256 ]
DataPattern (32-bit hex value or 'Default') [Default]
StopOnError (True / False) [True ]
LoopForever (True / False) [False ]
Do you want to start the test? (y/n) [n] y
See also
test cancel
, page 289
test status
, page 292
test switch
, page 294
Summary of Contents for StorageWorks SN6000
Page 16: ...16 Command Line Interface Usage ...
Page 20: ...20 User Account Configuration ...
Page 34: ...34 Network Configuration ...
Page 82: ...82 Zoning Configuration ...
Page 86: ...86 Connection Security Configuration ...
Page 96: ...96 Device Security Configuration ...
Page 100: ...100 RADIUS Server Configuration ...
Page 124: ...124 Simple Network Management Protocol Configuration ...
Page 318: ...318 Command Reference ...
Page 330: ...330 Index ...