132 Command Reference
capture
Description
Manages the data capture configuration for the Tech_Support_Center Call Home profile. The data
capture configuration determines the time and frequency by which status and trend data are
collected from the switch and sent to recipients specified in the Tech_Support_Center profile.
Authority
Admin session and Callhome Edit session. For information about starting a Callhome Edit session,
see the
callhome
command.
Syntax
capture
add
edit
remove
Operands
add
Adds data capture instructions to the Tech_Support_Center profile.
Table 7
describes the data
capture parameters.
Table 7
Data capture configuration parameters
Parameter
Description
TimeOfDay
Time of day to send status and trend data to the
Tech_Support_Center profile email recipients. The format is hh:mm
on a 24-hour clock. The default 02:00.
DayOfWeek
Day of the week to send status and trend data to the
Tech_Support_Center profile email recipients. Values can be
Sun
,
Mon
,
Tue
,
Wed
,
Thur
,
Fri
,
Sat
. The default is Sat.
Interval
Number of weeks between data-capture emails to the
Tech_Support_Center profile email recipients. Values can be 1–26.
The default is 1.
edit
Opens an edit session in which to modify the data capture configuration of the
Tech_Support_Center profile. See
Table 7
for a description of the data capture configuration
parameters.
remove
Removes the data capture configuration from the Test_Support_Center profile.
Summary of Contents for StorageWorks SN6000
Page 16: ...16 Command Line Interface Usage ...
Page 20: ...20 User Account Configuration ...
Page 34: ...34 Network Configuration ...
Page 82: ...82 Zoning Configuration ...
Page 86: ...86 Connection Security Configuration ...
Page 96: ...96 Device Security Configuration ...
Page 100: ...100 RADIUS Server Configuration ...
Page 124: ...124 Simple Network Management Protocol Configuration ...
Page 318: ...318 Command Reference ...
Page 330: ...330 Index ...