2–76
edge switch 2/24 service manual
Diagnostics
30
The attached device is causing the recurrent link incident. Notify the customer of the
problem and have the system administrator:
a. Inspect and verify operation of the attached device.
b. Repair the attached device if a failure is indicated.
c. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
NO
↓
The attached device, Fibre Channel link, and switch appear operational. Exit
MAP.
Contact the next level of support. Exit MAP.
31
The switch port reporting the problem is causing the recurrent link incident. The
recurring link incident indicates port degradation and a possible pending failure. Go to
step 6
.
32
Does the EWS interface appear operational?
NO
YES
↓
Go to
step 36
.
33
A Page cannot be found, Unable to locate the server, HTTP 404 - file not found,
or other similar message appears. The message indicates the web browser PC
cannot communicate with the switch because:
•
The switch-to-PC Internet link could not be established.
•
AC power distribution in the switch failed, or AC power was disconnected.
•
The switch CTP failed.
Continue.