![HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual Download Page 236](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139236.webp)
B–22
edge switch 2/24 service manual
Event Codes
Event Code: 302
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Three cooling fans (out of six) failed or are rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of the power
supply assembly (or assemblies) associated with the failed fans.
Action:
Replace the power supply assembly (or assemblies) containing the indicated fan
modules.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5
inclusive).
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Event Code: 303
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Four cooling fans (out of six) failed or are rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of both power
supply assemblies.
Action:
Replace both power supply assemblies.
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5
inclusive).
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔