edge switch 2/24 service manual
2–35
Diagnostics
MAP 0200: POST Failure Analysis
When the switch is powered on, it performs a series of power-on self-tests (POSTs). When
POSTs complete, the switch performs an initial program load (IPL) that loads firmware and
brings the unit online. This MAP describes fault isolation for problems that may occur during
the POST/IPL process.
If an error is detected, the POST/IPL process continues in an attempt to initialize the switch
and bring it online. An event code
400
is displayed when the switch completes the POST/IPL
process.
1
Ensure the switch reporting the problem is connected to facility AC power. Inspect the
switch for indications of being powered on, such as:
•
At the front bezel, an illuminated power LED (green) or system error LED
(amber).
•
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES
NO
↓
An AC power distribution problem is indicated, and analysis for the failure is
not described in this MAP. Go to
MAP 0100: Power Distribution Analysis on
page 2-27
. Exit MAP.
2
Was an event code 400, or 411, or 413 observed at the Edge Switch 2/24 Event Log
or at the EWS Event Log?
YES
NO
↓
Analysis for the failure is not described in this MAP. Go to
MAP 0000: Start
MAP on page 2–6
. Exit MAP.