Event Code: 507
Message:
Loopback diagnostics port failure.
Severity:
Informational.
Explanation:
A loopback diagnostic test detected a Fibre Channel port failure.
Action:
No action required. An event code 506 is generated if this diagnostic failure results in a
hard port failure.
Event Data:
Byte 0 = port number (00 through 23).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 through 11 = reason code specific.
Byte 12 = test type.