![HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual Download Page 249](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139249.webp)
edge switch 2/24 service manual
B–35
Event Codes
Port Events (500 through 599)
Event Code: 506
Message:
Fibre Channel port failure.
Severity:
Major.
Explanation:
A Fibre channel port failed. The amber LED corresponding to the port illuminates to
indicate the failure. Other ports remain operational if their LEDs are extinguished.
Action:
Perform the data collection procedure and return the Zip disk to Hewlett-Packard
support personnel.
Perform a switch reset. If the problem persists, replace the switch.
Event Data:
Byte 0 = port number (00 through 23).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 through 11 = reason code specific.
Byte 16 = connector type.
Bytes 17 and 18 = transmitter technology.
Byte 19 = distance capabilities.
Byte 20 = supported transmission media.
Byte 21 and 22 = speed capability and configuration.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔