![HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual Download Page 194](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139194.webp)
A–24
edge switch 2/24 service manual
Messages
Are you sure you
want to send
firmware version?
This message
requests confirmation
to send a firmware
version from the
HAFM server’s
firmware library to the
switch or director.
Click Yes to send the
firmware version or No to
abort the operation.
Cannot disable
Switch Binding while
Enterprise Fabric
Mode is active and
the switch is Online.
A user attempted to
disable switch
binding through the
Switch Binding
Change State dialog
box, but Enterprise
Fabric Mode is
enabled.
Either disable Enterprise
Fabric Mode using the
Enterprise Fabric Mode
dialog box at the HAFM
application, or set the switch
offline to disable switch
binding.
Cannot disable
Insistent Domain ID
while Fabric Binding
is active.
A user attempted to
disable the Insistent
Domain ID parameter
through the
Configure Switch
Parameters dialog
box, but fabric
binding is enabled.
Disable fabric binding through
the Fabric Binding dialog
box before disabling the
parameter.
Cannot enable
beaconing on a failed
FRU.
Message occurs
when selecting
Enable Beaconing for
a failed FRU.
Replace the FRU and enable
beaconing or enable
beaconing on an operating
FRU.
Cannot enable
beaconing while the
system error light is
on.
Beaconing cannot be
enabled while the
system error LED is
illuminated.
Select Clear System Error
Light from the Product menu
to clear the error light, then
enable beaconing.
Cannot have spaces
in field.
Spaces are not
allowed as part of the
entry for this field.
Delete spaces from the field
entry.
Cannot install
firmware to a switch
with a failed CTP
card.
Firmware cannot be
installed on a switch
with a failed CTP
card.
The CTP card failed and is
not a FRU. Replace the
switch.
Message Description
Action