3–14
edge switch 2/24 service manual
Repair Information
Offline
Off
Off
Off
Off
None
Yellow
Triangle
The port is blocked and transmitting
the offline sequence (OLS) to the
attached device.
The port is unblocked and receiving
the OLS, indicating the attached
device is offline.
Beaconi
ng
Off, On, or
Blinking
Blinking
Yellow
Triangle
The port is beaconing. The amber port
LED blinks once every two seconds to
enable users to locate the port.
Invalid
Attach
ment
On
Off
Yellow
Triangle
The port has an invalid attachment.
The reason appears in the Reason
field at the Port Properties dialog
box.
Link
Incident
Off
Off
Yellow
Triangle
A link incident occurred. The alert
symbol appears at the Hardware
View and Port List View.
Link
Reset
Off
Off
Yellow
Triangle
The switch and attached device are
performing a link reset operation to
recover the link connection. This is a
transient state that should not persist.
No
Light
Off
Off
None
No signal (light) is received at the
switch port. This is a normal condition
when there is no cable attached to the
port or when the attached device is
powered off.
Inactive
On
Off
Yellow
Triangle
The port is inactive. The reason
appears in the Reason field at the
Port Properties dialog box.
Not
Installe
d
Off
Off
None
An optical transceiver is not installed
in the switch port.
Table 3–2: Port Operational States (Continued)
Port
State
Blue/Green
LED
Amber
LED
Alert
Symbol
Description