![HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual Download Page 23](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139023.webp)
edge switch 2/24 service manual
2–3
Diagnostics
070
E_Port is segmented.
Go to
MAP 0700
.
071
Switch is isolated.
Go to
MAP 0700
.
072
E_Port connected to unsupported switch.
Go to
MAP 0700
.
073
Fabric initialization error.
Refer to
Collecting
Maintenance Data on page
3–22
.
074
ILS frame delivery error threshold
exceeded.
Refer to
Collecting
Maintenance Data on page
3–22
.
080
Unauthorized worldwide name.
Go to
MAP 0600
.
081
Invalid attachment.
Go to
MAP 0600
120
Error while processing system
management command.
Go to
MAP 0600
121
Zone set activation failed - zone set too
large.
Reduce size of zone set
and retry.
200
Power supply AC voltage failure.
Go to
MAP 0100
.
201
Power supply DC voltage failure.
Go to
MAP 0100
.
203
Power supply AC voltage recovery.
No action required.
204
Power supply DC voltage recovery.
No action required.
206
Power supply removed.
Replace FRU.
207
Power supply installed.
No action required.
300
Cooling fan propeller failed.
Go to
MAP 0500
.
301
Cooling fan propeller failed.
Go to
MAP 0500
.
302
Cooling fan propeller failed.
Go to
MAP 0500
.
303
Cooling fan propeller failed.
Go to
MAP 0500
.
304
Cooling fan propeller failed.
Go to
MAP 0500
.
305
Cooling fan propeller failed.
Go to
MAP 0500
.
310
Cooling fan propeller recovered.
No action required.
311
Cooling fan propeller recovered.
No action required.
312
Cooling fan propeller recovered.
No action required.
Table 2–3: Event Codes versus Maintenance Action (Continued)
Event
Code
Explanation
Action