![HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual Download Page 255](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139255.webp)
edge switch 2/24 service manual
B–41
Event Codes
Event Code: 525
Message:
FL_Port arbitration timeout.
Severity:
Informational.
Explanation:
A switch port could not win loop arbitration within the specified loop protocol time out
value (LP_TOV).
Action:
Switch firmware reinitializes the arbitrated loop. No user action required.
Event Data:
Byte 0 = port number (00 through 23).
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 581
Message:
Implicit incident.
Severity:
Major.
Explanation:
An attached open systems interconnection (OSI) server recognized a condition caused
by an event that occurred at the server. The event caused an implicit Fibre Channel link
incident.
Action:
A link incident record (LIR) is generated and sent to the attached server using the
reporting procedure defined in T11/99-017v0 (OSI). If fault isolation at the server does
not detect a failure, the problem may be due to a port failure. Go to
MAP 0000: Start
MAP on page 2–6
to perform fault isolation.
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔