B–18
edge switch 2/24 service manual
Event Codes
Power Supply Events (200 through 299)
Event Code: 200
Message:
Power supply AC voltage failure.
Severity:
Major.
Explanation:
Alternating current (AC) input to the indicated power supply is disconnected or AC
circuitry in the power supply failed. The second power supply assumes the full operating
load for the switch.
Action:
Ensure the power supply is connected to facility AC power, and verify operation of the
facility power source. If the AC voltage does not recover (indicated by event code 203),
replace the failed power supply. Perform the data collection procedure and return the Zip
disk and failed power supply to Hewlett-Packard support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Event Code: 201
Message:
Power supply DC voltage failure.
Severity:
Major.
Explanation:
Direct current (DC) circuitry in the power supply failed. The second power supply
assumes the full operating load for the switch.
Action:
Replace the failed power supply. Perform the data collection procedure and return the
Zip disk and failed power supply to Hewlett-Packard support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔