![HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual Download Page 30](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139030.webp)
2–10
edge switch 2/24 service manual
Diagnostics
Does the switch appear powered on?
YES
NO
↓
A power distribution problem is indicated. Go to
step 21
to obtain event
codes. If no event codes are found, go to
MAP 0100: Power Distribution
Analysis on page 2–27
. Exit MAP.
9
At the switch, inspect the amber LED on the switch.
Is the amber LED illuminated on the switch?
NO
YES
↓
Failure of the CTP is indicated. Event codes are not recorded. Go to
MAP
0500: FRU Failure Analysis on page 2-59
. Exit MAP.
10
A switch-to-server Ethernet link failure is indicated.
Go to
step 21
to obtain event codes. If no event codes are found, go to
MAP 0400:
Loss of Console Communication on page 2-44
.
Exit MAP.
11
Does a red diamond with yellow background (failure indicator) appear as the
background to the icon representing the switch reporting the problem?
YES
NO
↓
Go to
step 13
.
12
Double-click the icon representing the switch reporting the problem. The Hardware
View displays. At the Hardware View:
•
Observe the Edge Switch 2/24 Status table is yellow and the switch status is
NOT OPERATIONAL.
•
Inspect FRUs for a blinking red and yellow diamond (failed FRU indicator) that
overlays the FRU graphic.