![HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual Download Page 31](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139031.webp)
edge switch 2/24 service manual
2–11
Diagnostics
Do blinking red and yellow diamonds overlay FRU graphics?
NO
YES
↓
Failure of all installed FRUs is indicated. Go to
step 21
to obtain event codes.
If no event codes are found, go to
MAP 0700: Fabric, ISL, and Segmented
Port Problem Determination on page 2-79
. Exit MAP.
13
Does a yellow triangle (attention indicator) appear as the background to the icon
representing the switch reporting the problem?
YES
NO
↓
Go to
step 16
.
14
Double-click the icon representing the switch reporting the problem. The Hardware
View displays. At the Hardware View:
•
Observe the Edge-24 Status table is yellow and the switch status is Minor
Failure or Redundant Failure.
•
Inspect FRUs for a blinking red and yellow diamond
(failed FRU indicator) that overlays the FRU graphic.
Does a blinking red and yellow diamond overlay a power supply graphic?
NO
YES
↓
A power supply failure is indicated. Go to
step 21
to obtain event codes. If no
event codes are found, go to
MAP 0100: Power Distribution Analysis on
page 2-27
. Exit MAP.
15
Does a blinking red and yellow diamond overlay a FRU graphic?
NO
YES
↓
A port failure is indicated. Go to
step 21
to obtain event codes. If no event
codes are found, go to
MAP 0700: Fabric, ISL, and Segmented Port Problem
Determination on page 2-79
.
Exit MAP.