![HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual Download Page 254](http://html.mh-extra.com/html/hp/316095-b21-storageworks-edge-switch-2-24/316095-b21-storageworks-edge-switch-2-24_service-manual_164139254.webp)
B–40
edge switch 2/24 service manual
Event Codes
Event Code: 523
Message:
FL_Port open request failed.
Severity:
Informational.
Explanation:
When the indicated FL_Port attempted to open a loop device, the port open (OPN)
sequence was returned.
Action:
No action required.
Event Data:
Byte 0 = port number (00 through 23).
Byte 1 = arbitrated loop physical address (AL_PA) of the device transmitting the OPN
sequence.
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 524
Message:
No AL_PA acquired.
Severity:
Informational.
Explanation:
Switch cannot allocate an AL_PA of 0 (loop master) for an FC-AL device during loop
initialization. The device cannot participate in loop operation.
Action:
Disconnect the FC-AL device that is loop master.
Event Data:
Byte 0 = port number (00 through 23).
Distribution:
Switch
HAFM Server
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔