3–24
edge switch 2/24 service manual
Repair Information
3. At the navigation control panel, select Set Online State from the Maintenance
menu. If the switch is offline, the Set Online State dialog box displays, indicating
the state is OFFLINE.
Figure 3–13: Set Online Warning dialog box
4. Click Set Online. A Warning dialog box displays, indicating the switch is to be
set online.
5. Click OK. As the switch comes online, inspect the Product Manager application.
The State field of the Status table displays Online.
Set Offline State
To set the switch offline:
1. Notify the customer the switch is to be set offline. Ensure the customer’s system
administrator quiesces Fibre Channel frame traffic through the switch and sets
attached devices offline.
2. At the HAFM server, open the HAFM application. The Product View displays.
3. Select the icon representing the switch to be set offline. The Hardware View for
the selected switch displays.
4. At the navigation control panel, select Set Online State from the Maintenance
menu. If the switch is online, the Set Online State dialog box displays, indicating
the state is ONLINE.
Figure 3–14: Set Offline Warning dialog box
5. Click Set Offline. A Warning dialog box displays, indicating the switch is to be
set offline.
6. Click OK. As the switch goes offline, inspect the Product Manager application.
The State field of the Status table displays OFFLINE.