MAINTENANCE
7-102
Check Air Conditioner Condenser
--- every 6 months
If condenser (1) is covered with dirt and/or insects, air
conditioner cooling performance will be reduced. Remove
dirt or stain foreign material from fins of condenser (1)
using tap water. In case the condenser has been severely
contaminated, use a soft brush or a plastic fin comb tool.
Do not use a hard brush, which may damage the fins.
Check Air Conditioner Compressor Belt
--- every 6 months
Check the belt for abnormal deflection and damage. Check
HVAC belt tension by using tension gauge.
Belt tension: 412±49 N (42±5 kgf, 93±11 Ibf)
f
NOTE: The belt tension should be 588±98 N (60±10 kgf,
132±22 lbf) when the belt is replaced with new one.
Compressor Belt Tension Adjustment Procedure
1. Loosen lock nuts (2, 6) of tension pulley (4).
2. Remove plate (5) and tension pulley (4) to adjust belt
tension by turning belt tension adjustment bolt (3).
3. After adjustment, securely tighten lock nuts (2, 6) and
mount plate (5).
Nut (2): 52.5 N·m (5.35 kgf·m, 38.7 lbf·ft)
1
115Z7B-7-102-1
95Z7-7-92-2
Summary of Contents for ZW 550-6
Page 4: ......
Page 10: ...CONTENTS SPECIFICATIONS 12 1 Specifications 12 1 Intended Use 12 1 INDEX 14 1 ...
Page 12: ...MACHINE NUMBERS 2 Aftertreatment Device SCR TYPE MFG NO DOC TYPE MFG NO 95Z7B SCR4 95Z7B SCR4 ...
Page 54: ...SAFETY LABELS S 42 2 25 7 4 1 26 1 8 9 5 6 11 12 10 24 115Z7B S 42US ...
Page 148: ...OPERATOR S STATION 1 84 MEMO ...
Page 208: ...OPERATOR S STATION 1 144 MEMO ...
Page 210: ...BREAK IN 2 2 MEMO ...
Page 226: ...OPERATING THE ENGINE 3 16 MEMO ...
Page 274: ...OPERATING THE MACHINE 5 28 MEMO ...
Page 354: ...MAINTENANCE 7 70 MEMO ...
Page 418: ...9 4 MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS MEMO ...
Page 422: ...10 4 STORAGE MEMO ...
Page 428: ...11 6 TROUBLESHOOTING MEMO ...
Page 430: ...SPECIFICATIONS 12 2 MEMO ...
Page 438: ...INDEX 14 8 ZW550 6 US MEMO ...