54
d
Supplementary explanation of AT command
■
Commands which do not function
The following commands do not generate errors but will not function as a command:
・
ATT (Tone setting)
・
ATP (Pulse setting)
■
Command name: +CGDCONT
・
Outline
Sets the access point name (APN) for packet origination.
Though this command is a setting command, it will not be recorded in non-volatile memory written by [&W], nor
reset by [&F] or [Z].
・
Format
+CGDCONT=[ <cid>[ ,“PPP”[ ,“<APN>”] ] ]
・
Explanation of the parameters
Sets the access point name (APN) for packet origination. See the following command execution example:
<cid>
*
:
1 ~ 10
<APN>
*
:
Any value
*
:
<cid> is a number for managing the access point name (APN) registered in the FOMA terminal for a packet
communication. For the FOMA terminal, you can register from number 1 to 10. As “mopera.ne.jp” is assigned to
<cid>=1 and “mopera.net” is assigned to <cid>=3 by default, assign to cid2 or cid4 to cid10.
<APN> is an arbitrary character string indicating each access point name.
・
Operation performed when the parameter is omitted
+CGDCONT=
:
Sets the initial value to all <cid>.
+CGDCONT=<cid>
:
Sets the specified <cid> to the initial value.
+CGDCONT=?
:
Displays a list of values that can be set.
+CGDCONT?
:
Displays the current setting.
・
Command execution example
Command for registering an APN name of abc (when cid is 2).
AT+CGDCONT=2,“PPP”,“abc”
OK
■
Command name: +CGEQMIN=[parameter]
・
Outline
Registers a criterion to be used to decide whether or not to allow the QoS (quality of service) that is informed from
the network side when PPP packet communication is established.
There are 4 setting patterns as described in the following command execution example.
Though this command is a setting command, it will not be recorded in non-volatile memory written by [&W], nor
reset by [&F] or [Z].
・
Format
+CGEQMIN=[<cid>[ ,,<Maximum bitrate UL>[ ,<Maximum bitrate DL>] ] ]
・
Explanation of the parameters
<cid>
*
:
1
〜
10
<Maximum bitrate UL>
*
:
None (initial value) or 64
<Maximum bitrate DL>
*
:
None (initial value) or 384
*
:
<cid> is a number for managing the access point name (APN) registered in the FOMA terminal for a packet
communication. For the FOMA terminal, you can register from number 1 to 10. As “mopera.ne.jp” is assigned to
<cid>=1 and “mopera.net” is assigned to <cid>=3 by default, assign to cid2 or cid4 to cid10. <Maximum bitrate
UL> and <Maximum bitrate DL> set the minimum communication speed (kbps) of uplink and downlink between
the FOMA terminal and base station. When it is set to “None” (initial value), all speeds will be permitted, but
when set to 64 or 384, a connection at a speed of other values will not be permitted, and a packet
communication may not be connected.
・
Operation performed when the parameter is omitted
+CGEQMIN=
:
Sets the initial value to all <cid>.
+CGEQMIN=<cid>
:
Sets the specified <cid> to the initial value.
+CGEQMIN=?
:
Displays a list of values that can be set.
+CGEQMIN?
:
Displays the current setting.
Summary of Contents for N903i
Page 208: ......
Page 499: ...497 dIndex Quick Manual Index 498 Quick Manual 506 ...
Page 576: ...Kuten Code List ...