InteliDrive DCU Industrial 3.4.0 Global Guide
13
Statistic values
It is calculated:
1
Run Hours
Each finished 60 minutes when engine is running.
2
NumSuccStarts
Each successful start (starter is switched off due to RPM> Starting RPM) is
calculated.
Each external (manual) engine start.
3
NumUnscStarts
Each finished unsuccessful cranking - MaxCrank time is over and engine is not
started.
4
Service Time
It is decreased each finished 60 minutes when engine is running.
5
DayCons
Daily fuel consumption, every liter of fuel is calculated.
6
TripCons
Trip fuel consumption, every liter of fuel is calculated.
7
Memo1
Each time rising edge is detected with LBI: Memo1 Trigger
8
Memo2
Each time rising edge is detected with LBI: Memo2 Trigger
9
MomAvgFlCon L
Momentary average fuel consumption per nautical mile. Calculated from fuel
consumption and boat speed.
Result is not rounded, e.g. 9/100 is displayed as 0,0
If FuelConsumpt is 0 then MomAvgFlCon L is displayed as invalid value #####.
Note:
Statistic values can be adjusted from InteliMonitor, password 3 level protected by default.
Note:
Internal display does not support Unsigned Long values so it does not display correctly values higher
than 2,147,483,647. Could be roughly says that issue is connected with values having 10 digits and more.If
there is higher value, it treats it as Signed long and show it as negative with "-" (minus sign).Workaround: If
numbers with 10 digits has unlogically minus mark number should be recalculated.
History records
Following table does not contain Wrn, Sd and Fls messages from external units.
Events specification
Protection type
Information available on binary output
Alarms
Wrn Analog input 1 to 8
WRN
YES
Sd Analog input 1 to 8
SD
YES
ID-DCU Industrial Binary input 1 to 14
Configurable
YES
ID-DCU Industrial Battery voltage <, >
WRN
YES
Wrn SHBIN 1 to 6
WRN
Sd SHBIN 1 to 6
SD
Wrn DISTBIN 1 to 32
WRN
Sd DISTBIN 1 to 32
SD
Wrn SHAIN 1 to 4
WRN
Sd SHAIN 1 to 4
SD
Wrn CommError(1) to (10)
WRN
Summary of Contents for InteliDrive DCU Industrial
Page 5: ...InteliDrive DCU Industrial 3 4 0 Global Guide 5 8 2 13 Theory of binary inputs and outputs 347...
Page 29: ...InteliDrive DCU Industrial 3 4 0 Global Guide 29...
Page 97: ...InteliDrive DCU Industrial 3 4 0 Global Guide 97 8 Appendix 6 back to Table of contents...
Page 246: ...InteliDrive DCU Industrial 3 4 0 Global Guide 246 Analog inputs from J1939 configuration...
Page 263: ...InteliDrive DCU Industrial 3 4 0 Global Guide 263 6 back to List of setpoints...