InteliDrive DCU Industrial 3.4.0 Global Guide
139
Setpoint group
Load sharing
Related FW
3.4.0
Range [units]
0.0 .. ClutchMaxSpeed [%]
Default value
0.0
Force value
Alternative config
Step
0.1
Comm object
10096
Related applications
AS
Description
Clutch can be switched on if
ClutchMinSpeed
< RPM <
ClutchMaxSpeed
. Limits are in % of the
Requested speed. See
Function description details (page 63)
Note:
0.0 % corresponds to (Idle speed + Idle offset) value, 100.0 % corresponds to Nominal speed.
ClutchMinSpeed
Setpoint group
Load sharing
Related FW
3.4.0
Range [units]
ClutchMinSpeed .. 100.0 [%]
Default value
100.0
Force value
Alternative config
Step
0.1
Comm object
10097
Related applications
AS
Description
Clutch can be switched on if
ClutchMinSpeed
< RPM <
ClutchMaxSpeed
. Limits are in % of Requested
speed. See
Function description details (page 63)
Note:
0.0 % corresponds to (Idle speed + Idle offset) value, 100.0 % corresponds to Nominal speed.
ClutchMaxSpeed
Summary of Contents for InteliDrive DCU Industrial
Page 5: ...InteliDrive DCU Industrial 3 4 0 Global Guide 5 8 2 13 Theory of binary inputs and outputs 347...
Page 29: ...InteliDrive DCU Industrial 3 4 0 Global Guide 29...
Page 97: ...InteliDrive DCU Industrial 3 4 0 Global Guide 97 8 Appendix 6 back to Table of contents...
Page 246: ...InteliDrive DCU Industrial 3 4 0 Global Guide 246 Analog inputs from J1939 configuration...
Page 263: ...InteliDrive DCU Industrial 3 4 0 Global Guide 263 6 back to List of setpoints...