LCD Message
Description
Corrective Action
E27 Lost Failover
Target
Unable to find the backup TeraStation.
Reconfigure the backup TeraStation for
failover by referring to the
section in chapter 5.
E30 Replace Drive
x
An error occurred, so the drive was
removed from the RAID array.
Replace the drive by referring to the drive
replacement sections in chapter 8.
E41 NVRAM Failure
The NVRAM inside the TeraStation failed.
Contact Buffalo technical support for
assistance.
Status
After you change settings, one of the following messages will appear on the LCD panel and the info LED will glow
amber. You can also confirm the current status from the Dashboard in Settings or using NAS Navigator2. However,
NAS Navigator2 may show the status as an unknown error. In such a case, check the Dashboard in Settings.
You can click the “Clear” button to delete messages from the Dashboard.
Note:
The “x” in the LCD message is the number of the drive, array, or job involved in the process.
LCD Message
Description
Corrective Action
I01 Rebuilding
System Array
Checking the system area.
-
I10 System Is
Overheating
A rise in the system temperature may have
exceeded the allowable safety value.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
I11 Bad Sectors on
Drive
x
The drive has too many bad sectors.
Replace the drive by referring to the drive
replacement sections in chapter 8.
I12 Degraded Mode
Operating in degraded mode.
Check if the E30 message is also displayed.
In such a case, refer to the corrective action
for the E30 message.
I13 Formatting Array
x
...
Formatting the RAID array.
-
I14 Checking Array
x
...
Checking the RAID array.
-
I15 Scanning Array
x
Data...
Examining the error status of the RAID
array.
Note:
Transfer speeds are slower during
the examination process.
-
I16 Creating Array
x
...
Creating the RAID array.
-
I18 Rebuilding Array
x
...
Rebuilding the RAID array.
Note:
Transfer speeds are slower during
the rebuilding process.
-
I19 Rewriting Array
x
...
Rewriting the RAID array.
-
I20 Formatting Drive
x
...
Formatting the drive.
-
I21 Checking Drive
x
...
Checking the drive.
-
I22 Rewriting Drive
x
...
Rewriting the drive.
-
I25 Updating
Firmware...
Updating the TeraStation firmware.
Note:
Do not turn off the TeraStation’s
power.
-
221
Chapter 10 Appendix
Summary of Contents for TeraStation 6000 Series
Page 32: ...3 Click Add Group 31 Chapter 3 File Sharing...
Page 120: ...2 Click Time Machine 119 Chapter 5 Backup...
Page 121: ...3 Click Select Backup Disk 4 Select the TeraStation then click Use Disk 120 Chapter 5 Backup...
Page 123: ...7 Time Machine will count down from 120 seconds then backup will begin 122 Chapter 5 Backup...
Page 132: ...5 Click Edit 131 Chapter 6 Remote Access...
Page 144: ...4 Click the Options tab 5 Click Edit 143 Chapter 6 Remote Access...
Page 153: ...4 Click the Options tab 152 Chapter 6 Remote Access...
Page 154: ...5 Click Edit 153 Chapter 6 Remote Access...
Page 169: ...11Click the NFS Rules tab 12Click Add 168 Chapter 7 Advanced Features...