LCD Message
Description
Corrective Action
Date and Time
Date Time
YYYY/MM/DD
hh:mm
Displays the date and time set in the
TeraStation.
-
IP Address
LAN
x
DHCP
192.168.11.150
Displays the IP address. If acquiring from a
DHCP server automatically, “DHCP” will be
displayed. If configuring a static IP address,
“Static IP” will be displayed.
-
LAN
x
Port Trunking
Displays if port trunking is configured.
-
Errors
If an error occurs, one of the following messages will appear on the LCD panel and the error LED will glow red. You
can also confirm the current status from Settings or using NAS Navigator2. However, NAS Navigator2 may show the
error as an unknown error. In such a case, check the Dashboard in Settings.
Note:
The “x” in the LCD message is the number of the drive or array involved in the process.
LCD Message
Description
Corrective Action
E10 UPS Running Off
Battery
The TeraStation is running on the UPS
battery due to a power outage.
Shut down the TeraStation safely and wait
until the power outage ends. If certain
settings are configured, the TeraStation
may shut down automatically when the
error is detected.
If the setting to use the UPS connected to
this TeraStation has been configured, the
UPS cable may be disconnected.
Verify that the UPS cable or LAN cable is
connected properly.
If the setting to use the UPS connected to
another TeraStation on the same network
has been configured, the LAN cable of this
TeraStation may be disconnected.
E11 Fan Failure
An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects
or dust are found, use a pair of tweezers,
air duster, or other tools to remove them.
If the error is displayed again, contact
Buffalo technical support for assistance.
E12 Cooling Failure
A rise in the system temperature may have
exceeded the allowable safety value.
Do not place objects in the area around
the TeraStation. Also, move the TeraStation
to a cool location.
E14 Can’t Mount
Array
x
The RAID array cannot be mounted.
Run the drive check on the RAID array by
referring to the
section
in chapter 4.
E16 Drive
x
Not
Found
Unable to find the drive.
The drive may be disconnected or may
have failed. After shutting down, reinstall
the drive.
E22 Can’t Mount
Drive
x
Unable to mount the drive.
Format the drive. After formatting, if the
error still appears after rebooting, replace
the drive. If the error is displayed again,
contact Buffalo technical support for
assistance.
220
Chapter 10 Appendix
Summary of Contents for TeraStation 6000 Series
Page 32: ...3 Click Add Group 31 Chapter 3 File Sharing...
Page 120: ...2 Click Time Machine 119 Chapter 5 Backup...
Page 121: ...3 Click Select Backup Disk 4 Select the TeraStation then click Use Disk 120 Chapter 5 Backup...
Page 123: ...7 Time Machine will count down from 120 seconds then backup will begin 122 Chapter 5 Backup...
Page 132: ...5 Click Edit 131 Chapter 6 Remote Access...
Page 144: ...4 Click the Options tab 5 Click Edit 143 Chapter 6 Remote Access...
Page 153: ...4 Click the Options tab 152 Chapter 6 Remote Access...
Page 154: ...5 Click Edit 153 Chapter 6 Remote Access...
Page 169: ...11Click the NFS Rules tab 12Click Add 168 Chapter 7 Advanced Features...