6. Setup and configuration
2. In the
addresses
dialog box,
fi
ll out the desired value for the addresses.
-
Device address.
-
Common RC5 address
Image 6-7
3. Exit the menu.
6.5
Network con
fi
guration
Description
The MCM-50 can be connected to a network allowing it to be accessed from and controlled by a device within the same (local)
network. The network connection can be used for following:
•
fi
le transfer;
•
remote control;
•
MCM-50
fi
rmware upgrade;
•
debug logging;
•
debugging.
Two types of network con
fi
guration can be set:
•
Private subnet: unique
fi
xed IP addresses are used;
•
DHCP network: the MCM-50 is connected to a DHCP network where IP addresses are assigned automatically.
Network type
Description
Fixed IP
Manually assign an IP address, Subnet Mask, Default Gateway address.
•
Set the
IP address
to the desired value. It identi
fi
es the MCM-50 location on the local
network. The IP address must be unique within the local subnet.
•
Set the
Subnet Mask
as appropriate for the local subnet.
•
Set the
Default Gateway
to the IP address of the local router on the same local
network as this will be used to forward traf
fi
c to destinations beyond the local network.
If there is no router on the MCM-50 local network then set this
fi
eld to any unique IP
address on the local network.
DHCP
Enabling DHCP is meant for automatic IP address assignment.
A DHCP network lets network administrators centrally manage and automate the assignment
of IP addresses in an organization’s network. This is done by a DHCP server in the same
network. The DHCP server must be up and running at any time.
Depending on the lease time, a new IP address can be assigned to the MCM-50 on a
regular base.
Network settings
The Ethernet con
fi
guration settings of the MCM-50 are explained in the table below.
Parameter
Description
Type of
fi
eld
MAC Address
MAC Address of the MCM-50 (programmed
into the Ethernet board)
Informative only
IP Address (Current)
Current IP Address of the MCM-50
Informative only
Current Subnet Mask
Subnet Mask
Informative only
Current Gateway
Gateway
Informative only
Use Fixed IP
When this radio button is selected, the IP
address, Subnet Mask and Gateway (optional)
need to be entered manually.
Tickable radio button
R5909057 MCM-50 17/05/2016
29
Summary of Contents for MCM-50
Page 1: ...MCM 50 User Guide Optimized for F50 R5909057 02 17 05 2016...
Page 8: ...Table of contents 4 R5909057 MCM 50 17 05 2016...
Page 14: ...1 Safety instructions 10 R5909057 MCM 50 17 05 2016...
Page 20: ...3 Packaging 16 R5909057 MCM 50 17 05 2016...
Page 22: ...4 Facility and system requirements Image 4 1 18 R5909057 MCM 50 17 05 2016...
Page 28: ...5 Physical installation and connections 24 R5909057 MCM 50 17 05 2016...
Page 40: ...6 Setup and configuration Image 6 17 36 R5909057 MCM 50 17 05 2016...
Page 58: ...8 OSD Preferences 54 R5909057 MCM 50 17 05 2016...
Page 118: ...11 Expert operation 114 R5909057 MCM 50 17 05 2016...
Page 136: ...13 MCM 50 Tools 132 R5909057 MCM 50 17 05 2016...
Page 144: ...15 RCU Control 140 R5909057 MCM 50 17 05 2016...