AT32F425
Series Reference Manual
2022.03.30
Page 274
Ver 2.01
0: C1COUT is active high.
1: C1COUT is active low.
Bit 2
C1CEN
0x0
rw
Channel 1 complementary enable
0: Output is disabled.
1: Output is enabled.
Bit 1
C1P
0x0
rw
Channel 1 polarity
When the channel 1 is configured as output mode:
0: C1OUT is active high
1: C1OUT is active low
When the channel 1 is configured as input mode:
0: C1IN active edge is on its rising edge. When used as
external trigger, C1IN is not inverted.
1: C1IN active edge is on its falling edge. When used as
external trigger, C1IN is inverted.
Bit0
C1EN
0x0
rw
Channel 1 enable
0: Input or output is disabled
1: Input or output is enabled
Table 14-17 Com plem entary output channel CxOUT and CxCOUT control bits with break
function
Control bit
Output state
(1)
OEN bit FCSODIS bit
FCSOEN
bit
CxEN
bit
CxCEN
bit
CxOUT output state
CxCOUT output state
1
X
0
0
0
Output disabled
(no driven by the timer)
CxOUT=0, Cx_EN=0
Output disabled
(no driven by the timer)
CxCOUT=0, CxCEN=0
0
0
1
Output disabled
(no driven by the timer)
CxOUT=0, Cx_EN=0
polarity,
CxCOUT= CxORAW xor
CxCP, CxCEN=1
0
1
0
polarity
CxOUT= CxORAW xor CxP,
Cx_EN=1
Output disabled
(no driven by the timer)
CxCOUT=0, CxCEN=0
0
1
1
pdead-
time,
Cx_EN=1
CxORAW
ipdead-
time,
CxCEN=1
1
0
0
Output disabled
(no driven by the timer)
CxOUT=CxP, Cx_EN=0
Output disabled
(no driven by the timer)
CxCOUT=CxCP,
CxCEN=0
1
0
1
Off-state
(Output enabled with
inactive level)
CxOUT=CxP, Cx_EN=1
polarity,
CxCOUT= CxORAW xor
CxCP, CxCEN=1
1
1
0
polarity,
CxOUT= CxORAW xor CxP,
Cx_EN=1
Off-state
(Output enabled with
inactive level)
CxCOUT=CxCP,
CxCEN=1
1
1
1
pdead-
time, Cx_EN=1
CxORAW
ipdead-
time,
CxCEN=1
0
0
X
0
0
Output disabled
(no driven by the timer)
Asynchronously: CxOUT=CxP, Cx_EN=0,
CxCOUT=CxCP, CxCEN=0;
If the clock is present: after a dead-time,
CxOUT=CxIOS
,
CxCOUT=CxCIOS, assuming that
CxIOS and CxCIOS do not correspond to CxOUT and
CxCOUT active level.
0
0
1
0
1
0
0
1
1