Figure 19-2
Transmit interrupt generation
Inter-frame
space
Data frame (standard identifier)
44 + 8* N
Arbitration field
12
ID
6
Control field
Data field
8* N
CRC field
16
CRC
Ack field
2
7
EOF
DLC
S
O
F
R
T
R
ID
E
r0
A
C
K
Data frame ( extended identifier)
64 + 8* N
Inter-frame
space or
overload frame
ID
EOF
DLC
S
O
F
R
TR
ID
E
r0
A
C
K
Arbitration field
12
Arbitration field
20
Control field
6
8 * N
Data field
CRC field
16
CRC
Ack field
2
7
S
R
R
r1
Remote frame
44
Inter-frame
space or
overload frame
Arbitration field
12
ID
6
Control field
CRC field
16
CRC
DLC
Ack field
2
7
EOF
A
C
K
R
T
R
r0
ID
E
S
O
F
Data frame
or remote
frame
Error frame
Inter-frame
space or
overload frame
Error flag Error echo Error delimiter
6
6
8
Data frame or
remote frame
Intermission
Suspend
transmission
Bus idle
3
8
Any frame
End of frame or
error delimiter or
overload delimiter
Overload frame
Inter-frame space
or error frame
Overload
flag
Overload
echo
Overload
delimiter
6
6
8
Notes:
0 <= N <= 8
SOF = Start of frame
ID = Identifier
RTR = Remote transmission request
IDE = Identifier extension bit
r0 = Reserved bit
DLC = Data length code
CRC = Cyclic redundancy code
Error flag: 6 dominant bits if error
active; else, 6 recessive bits.
Suspend transmission: Only applies to
error passive node.
EOF = End of frame
ACK = Acknowledge bit
Inter-frame
space or
overload frame
Inter-frame space
Inter-frame
space
Inter-frame
space