Command reference
R&S
®
ZND
995
User Manual 1173.9557.02 ─ 61
Example:
ROSC EXT
Select the external reference clock as clock source.
ROSC:EXT:FREQ 10MHz
Specify the frequency of the external reference clock.
ROSC:EXT:FREQ?
Query the frequency of the external reference oscillator. The
response is 10000000 Hz.
Manual operation:
See
[SENSe<Ch>:]ROSCillator[:SOURce]
<Source>
Selects the source of the reference oscillator signal.
Parameters:
<Source>
INTernal | EXTernal
INTernal – internal 10 MHz reference oscillator
EXTernal – external reference clock
The frequency of the external reference clock can be defined
using
[SENSe:]ROSCillator:EXTernal:FREQuency
*RST:
INTernal
Example:
See
[SENSe:]ROSCillator:EXTernal:FREQuency
Manual operation:
See
7.3.14.12
[SENSe:]SEGMent...
The
[SENSe:]SEGMent<Seg>...
commands define all channel settings for a seg-
mented frequency sweep. A segmented sweep is activated via
SEGMent
.
The commands in this subsystem do not accept the step parameters UP and DOWN.
Numeric values can be entered directly or using the DEFault, MINimum, MAXimum
parameters.
................................................................................996
[SENSe<Ch>:]SEGMent<Seg>:BWIDth[:RESolution]
........................................................ 996
[SENSe<Ch>:]SEGMent<Seg>:BWIDth[:RESolution]:CONTrol
...........................................997
....................................................................................998
[SENSe<Ch>:]SEGMent<Seg>:DEFine
............................................................................998
[SENSe<Ch>:]SEGMent<Seg>:DEFine:SELect
.............................................................. 1000
[SENSe<Ch>:]SEGMent<Seg>:DELete:ALL
................................................................... 1000
[SENSe<Ch>:]SEGMent<Seg>:DELete[:DUMMy]
........................................................... 1001
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:CENTer?
.....................................................1001
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:SPAN?
........................................................1001
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STARt
.........................................................1001
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STOP
......................................................... 1001
SCPI command reference
www.allice.de
Allice Messtechnik GmbH