![ABB ACS880 Series Firmware Manual Download Page 628](http://html.mh-extra.com/html/abb/acs880-series/acs880-series_firmware-manual_2617628.webp)
Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0 / uint16
Calculated number of pole pairs in the motor.
This parameter is read-only.
Motor polepairs
calculated
99.15
1 = 1 / 1 = 1
Number of pole pairs.
0...1000
U V W / uint16
Switches the rotation direction of the motor. This
parameter can be used if the motor turns in the wrong
direction (for example, because of the wrong phase
order in the motor cable), and correcting the cabling
is considered impractical.
Note: Changing this parameter does not affect speed
reference polarities, so positive speed reference will
rotate the motor forward. The phase order selection
just ensures that "forward" is in fact the correct
direction.
Note: After changing this parameter, the sign of
encoder feedback (if any) must be checked. This can
be done by setting parameter
to
, and comparing the sign of
to
(or
). If the sign of the measurement
is incorrect, the encoder wiring must be corrected or
the sign of
reversed.
Note: This parameter cannot be changed while the
drive is running.
Motor phase order
99.16
0
Normal.
U V W
1
Reversed rotation direction.
U W V
0.000 mH / real32
Defines the inductance of a custom sine filter, i.e. when
parameter
bit 3 is activated.
Note: For an ABB sine filter (
bit 1), this parameter is set automatically and should
not be adjusted.
Sine filter
inductance
99.18
1000 = 1 mH / 1000 =
1 mH
Inductance of custom sine filter.
0.000 ... 100000.000
mH
628 Parameters
Summary of Contents for ACS880 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 22: ...22 ...
Page 24: ...24 ...
Page 44: ...44 ...
Page 66: ...66 ...
Page 148: ...148 ...
Page 168: ...168 ...
Page 704: ...704 ...
Page 728: ...728 ...
Page 742: ...742 ...
Page 762: ...762 ...