![ABB ACS880 Series Firmware Manual Download Page 499](http://html.mh-extra.com/html/abb/acs880-series/acs880-series_firmware-manual_2617499.webp)
Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0 = Status of follower 20 is monitored continuously.
1 = Status of follower 20 is monitored only when it is
in stopped state.
Follower 20
b3
0 = Status of follower 21 is monitored continuously.
1 = Status of follower 21 is monitored only when it is in
stopped state.
Follower 21
b4
0 = Status of follower 22 is monitored continuously.
1 = Status of follower 22 is monitored only when it is in
stopped state.
Follower 22
b5
0 = Status of follower 23 is monitored continuously.
1 = Status of follower 23 is monitored only when it is in
stopped state.
Follower 23
b6
0 = Status of follower 24 is monitored continuously.
1 = Status of follower 24 is monitored only when it is in
stopped state.
Follower 24
b7
0 = Status of follower 25 is monitored continuously.
1 = Status of follower 25 is monitored only when it is in
stopped state.
Follower 25
b8
0 = Status of follower 26 is monitored continuously.
1 = Status of follower 26 is monitored only when it is in
stopped state.
Follower 26
b9
0 = Status of follower 27 is monitored continuously.
1 = Status of follower 27 is monitored only when it is in
stopped state.
Follower 27
b10
0 = Status of follower 28 is monitored continuously.
1 = Status of follower 28 is monitored only when it is in
stopped state.
Follower 28
b11
0 = Status of follower 29 is monitored continuously.
1 = Status of follower 29 is monitored only when it is in
stopped state.
Follower 29
b12
0 = Status of follower 30 is monitored continuously.
1 = Status of follower 30 is monitored only when it is
in stopped state.
Follower 30
b13
0 = Status of follower 31 is monitored continuously.
1 = Status of follower 31 is monitored only when it is in
stopped state.
Follower 31
b14
0 = Status of follower 32 is monitored continuously.
1 = Status of follower 32 is monitored only when it is in
stopped state.
Follower 32
b15
1 = 1
0000h…FFFFh
60.0 s / uint16
Defines a wake-up delay during which no
master/follower communication faults or warnings are
generated. This is to allow all drives on the
master/follower link to power up.
The master cannot be started until the delay elapses
or all monitored followers are found to be ready.
M/F wake up delay
60.31
10 = 1 s / 10 = 1 s
Master/follower wake-up delay.
0.0 ... 180.0 s
Parameters 499
Summary of Contents for ACS880 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 22: ...22 ...
Page 24: ...24 ...
Page 44: ...44 ...
Page 66: ...66 ...
Page 148: ...148 ...
Page 168: ...168 ...
Page 704: ...704 ...
Page 728: ...728 ...
Page 742: ...742 ...
Page 762: ...762 ...