![ABB ACS880 Series Firmware Manual Download Page 164](http://html.mh-extra.com/html/abb/acs880-series/acs880-series_firmware-manual_2617164.webp)
■
Selection of constant speeds
By default, constant speeds 1…7 are selected using digital inputs DI4…DI6 as
follows:
Constant speed active
DI6
DI5
DI4
None (External speed reference used)
0
0
0
Constant speed 1
0
0
1
Constant speed 2
0
1
0
Constant speed 3
0
1
1
Constant speed 4
1
0
0
Constant speed 5
1
0
1
Constant speed 6
1
1
0
Constant speed 7
1
1
1
■
Default parameter settings for the Sequential control macro
Below is a listing of default parameter values that differ from those listed for the
Factory macro in
Sequential control macro default
Parameter
01b (Bit 0 = Packed)
600.00 rpm
900.00 rpm
1200.00 rpm
1500.00 rpm
2400.00 rpm
3000.00 rpm
0.12 s
164 Application macros