Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
10 = 1 s / 1000 = 1 s
Acceleration time 1.
0.000 ... 1800.000 s
20.000 s / real32
Defines deceleration time 1 as the time required for
the speed to change from the speed defined by
parameter
(not from parameter
) to zero.
If the speed reference decreases slower than the set
deceleration rate, the motor speed will follow the
reference.
If the reference changes faster than the set
deceleration rate, the motor speed will follow the
deceleration rate.
If the deceleration rate is set too short, the drive will
automatically prolong the deceleration in order not to
exceed drive torque limits (or not to exceed a safe DC
link voltage). If there is any doubt about the
deceleration time being too short, ensure that DC
overvoltage control is on (parameter
Note: If a short deceleration time is needed for a high
inertia application, the drive should be equipped with
braking equipment such as a brake chopper and brake
resistor.
Deceleration time 1
23.13
10 = 1 s / 1000 = 1 s
Deceleration time 1.
0.000 ... 1800.000 s
60.000 s / real32
Defines acceleration time 2. See parameter
.
Acceleration time 2
23.14
10 = 1 s / 1000 = 1 s
Acceleration time 2.
0.000 ... 1800.000 s
60.000 s / real32
Defines deceleration time 2. See parameter
Deceleration time 2
23.15
10 = 1 s / 1000 = 1 s
Deceleration time 2.
0.000 ... 1800.000 s
312 Parameters
Summary of Contents for ACS880 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 22: ...22 ...
Page 24: ...24 ...
Page 44: ...44 ...
Page 66: ...66 ...
Page 148: ...148 ...
Page 168: ...168 ...
Page 704: ...704 ...
Page 728: ...728 ...
Page 742: ...742 ...
Page 762: ...762 ...