Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
12
The start and stop commands are taken from fieldbus
adapter A.
Note: The start signal is always level-triggered with
this setting regardless of parameter
.
Fieldbus A
14
The start and stop commands are taken from the
embedded fieldbus interface.
Note: The start signal is always level-triggered with
this setting regardless of parameter
.
Embedded fieldbus
15
The start and stop commands are taken from another
drive through the master/follower link.
Note: The start signal is always level-triggered with
this setting regardless of parameter
.
M/F link
21
The start and stop commands are taken from the
application program control word (parameter
Note: The start signal is always level-triggered with
this setting regardless of parameter
.
Application Program
22
Reserved.
ATF
16
The start and stop commands are taken from an
external (DDCS) controller.
Note: The start signal is always level-triggered with
this setting regardless of parameter
.
DDCS controller
Edge / uint16
Defines whether the start signal for external control
location EXT1 is edge-triggered or level-triggered.
Note: This parameter is only effective when parameter
is set to
,
,
, or
.
Ext1 start trigger
type
20.2
0
The start signal is edge-triggered.
Edge
1
The start signal is level-triggered.
Level
DI1 / uint32
Selects source 1 for parameter
.
Ext1 in1 source
20.3
0
0 (always off).
Not selected
1
1 (always on).
Selected
2
Digital input DI1 (
, bit 0).
DI1
3
Digital input DI2 (
, bit 1).
DI2
4
Digital input DI3 (
, bit 2).
DI3
5
Digital input DI4 (
, bit 3).
DI4
Parameters 281
Summary of Contents for ACS880 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 22: ...22 ...
Page 24: ...24 ...
Page 44: ...44 ...
Page 66: ...66 ...
Page 148: ...148 ...
Page 168: ...168 ...
Page 704: ...704 ...
Page 728: ...728 ...
Page 742: ...742 ...
Page 762: ...762 ...