Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
10.00 Hz / real32
Defines the “at setpoint” limits for frequency control
of the drive. When the absolute difference between
reference (
) and actual
frequency (
) is smaller than
, the drive is considered to be
“at setpoint”. This is indicated by bit 8 of
.
Drive at setpoint
(
06.11
bit 8 = 1)
01.06
(Hz)
28.96
+
46.22
(Hz)
28.96
-
46.22
(Hz)
28.96
(Hz)
0 (Hz)
At frequency
hysteresis
46.22
- / -
Limit for “at setpoint” indication in frequency control.
For scaling, see parameter
0.00 ... 1000.00 Hz
10.0 % / real32
Defines the “at setpoint” limits for torque control of
the drive.
When the absolute difference between reference (
) and actual torque (
) is smaller than
, the
drive is considered to be “at setpoint”. This is indicated
by bit 8 of
.
Drive at setpoint
(
06.11
bit 8 = 1)
01.10
(%)
26.73
+
46.23
(%)
26.73
(%)
26.73
-
46.23
(%)
0 (%)
At torque hysteresis
46.23
- / -
Limit for “at setpoint” indication in torque control. For
scaling, see parameter
0.0 ... 300.0 %
1500.00 rpm / real32
Defines the trigger level for “above limit” indication in
speed control. When actual speed exceeds the limit,
bit 10 of
is set.
Above speed limit
46.31
454 Parameters
Summary of Contents for ACS880 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 22: ...22 ...
Page 24: ...24 ...
Page 44: ...44 ...
Page 66: ...66 ...
Page 148: ...148 ...
Page 168: ...168 ...
Page 704: ...704 ...
Page 728: ...728 ...
Page 742: ...742 ...
Page 762: ...762 ...