Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
10
Digital input/output DIO1 (
, bit
0).
DIO1
11
Digital input/output DIO2 (
, bit
1).
DIO2
12
Parameter
74.1 ESP control word (page 519)
, bit 10
status controls enable/disable status of the function.
ESP CW bit 10
See
Terms and abbreviations (page 169)
Other [bit]
10.00 Hz / real32
Defines frequency point 1 in the custom user U/F curve.
Frequency point 1
80.11
10 = 1 Hz / 100 = 1 Hz
Frequency point 1.
2.00 ... 600.00 Hz
20.00 Hz / real32
Defines frequency point 2 in the custom user U/F curve.
Frequency point 2
80.12
10 = 1 Hz / 100 = 1 Hz
Frequency point 2.
2.00 ... 600.00 Hz
30.00 Hz / real32
Defines frequency point 3 in the custom user U/F curve.
Frequency point 3
80.13
10 = 1 Hz / 100 = 1 Hz
Frequency point 3.
2.00 ... 600.00 Hz
40.00 Hz / real32
Defines frequency point 4 in the custom user U/F curve.
Frequency point 4
80.14
10 = 1 Hz / 100 = 1 Hz
Frequency point 4.
2.00 ... 600.00 Hz
45.00 Hz / real32
Defines frequency point 5 in the custom user U/F curve.
Frequency point 5
80.15
10 = 1 Hz / 100 = 1 Hz
Frequency point 5.
2.00 ... 600.00 Hz
50.00 Hz / real32
Defines frequency point 5 in the custom user U/F curve.
Frequency point 6
80.16
10 = 1 Hz / 100 = 1 Hz
Frequency point 6.
2.00 ... 600.00 Hz
55.00 Hz / real32
Defines frequency point 5 in the custom user U/F curve.
Frequency point 7
80.17
10 = 1 Hz / 100 = 1 Hz
Frequency point 7.
2.00 ... 600.00 Hz
60.00 Hz / real32
Defines frequency point 8 in the custom user U/F curve.
Frequency point 8
80.18
10 = 1 Hz / 100 = 1 Hz
Frequency point 8.
2.00 ... 600.00 Hz
Voltage / unit32
Selects the input mode for additive values in the
custom U/F curve.
Voltage correction
style
80.20
0
Additive value type for U/F curve selected as voltage.
Voltage
1
Additive value type for U/F curve selected as flux.
Flux
0.00% / real32
Defines additive point 1 in the custom user U/F curve.
The additive value type can be voltage of flux. This can
be selected in the parameter
.
Additive value 1
80.21
10 = 1% / 100 = 1%
Additive value 1.
-100.00 ... 100.00%
0.00% / real32
Defines additive point 2 in the custom user U/F curve.
Additive value 2
80.22
10 = 1% / 100 = 1%
Additive value 2.
-100.00 ... 100.00%
0.00% / real32
Defines additive point 3 in the custom user U/F curve.
Additive value 3
80.23
10 = 1% / 100 = 1%
Additive value 3.
-100.00 ... 100.00%
0.00% / real32
Defines additive point 4 in the custom user U/F curve.
Additive value 4
80.24
10 = 1% / 100 = 1%
Additive value 4.
-100.00 ... 100.00%
0.00% / real32
Defines additive point 5 in the custom user U/F curve.
Additive value 5
80.25
Parameters 547
Summary of Contents for ACS880 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 22: ...22 ...
Page 24: ...24 ...
Page 44: ...44 ...
Page 66: ...66 ...
Page 148: ...148 ...
Page 168: ...168 ...
Page 704: ...704 ...
Page 728: ...728 ...
Page 742: ...742 ...
Page 762: ...762 ...