Speed reference
75.16
75.15
75.62
75.69
Time
Time
Regular current
0
0
75.69
Pulse-start cycle 1
Pulse-start cycle 2
Last cycle
Note: Current pulse-start is applicable only for AC induction motors. For permanent
magnet motors, ABB recommends to use acceleration assistance (
75.40) and kick
start feature (
75.50), when regular starting routines are not enough to accelerate
the motor.
Settings and diagnostics
Parameter group
75 ESP reference setup (page 525)
■
Acceleration assistance
Acceleration assistance function enables the user to set motor current reference
used during acceleration. This setting makes the drive to extremely develop energy
in the motor that is necessary to accelerate high load at fast ramp rate. The function
works until the motor accelerates to a desired speed and then continues with
energy efficiency settings set by the user in group
.
Settings and diagnostics
Parameter group
.
Pump impeller cleaning
The Pump impeller cleaning procedure consists of a programmable sequence of
motor running forward and reverse for the defined number of cycles. The cleaning
ESP program features 51
Summary of Contents for ACS880 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 ESP control program option N5600 Firmware manual ...
Page 2: ......
Page 4: ......
Page 16: ...16 ...
Page 22: ...22 ...
Page 24: ...24 ...
Page 44: ...44 ...
Page 66: ...66 ...
Page 148: ...148 ...
Page 168: ...168 ...
Page 704: ...704 ...
Page 728: ...728 ...
Page 742: ...742 ...
Page 762: ...762 ...