78 Start-up
I/O settings mode
To view and edit the I/O settings, follow these steps:
1
Select MENU to enter the main
menu.
2
Scroll to I/O SETTINGS with the
UP/DOWN buttons and select
ENTER.
3
Scroll to the I/O setting you want
to view with the UP/DOWN
buttons and select SEL.
4
Select the setting you want to
view with the UP/DOWN buttons
and select EDIT.
5
You can change the value with
the UP/DOWN buttons and save
it by selecting SAVE.
If you do not want to change the
setting, select CANCEL.
6
Select EXIT to return to the main
menu.
0 A
0 %
0 mA
0.
0.
0.
0.0Hz
OFF
MENU
SP
I/O SETTINGS
PARAMETERS
ASSISTANTS
EXIT
ENTER
1
OFF
MAIN MENU
DIGITAL INPUTS (DI)
ANALOG INPUTS (AI)
RELAY OUTPUTS (ROUT)
ANALOG OUTPUTS (AOUT)
PANEL
I/O SETTINGS 1
EXIT
SEL
OFF
1001:START/STOP (EI1)
1002:START/STOP (EI1)
___
EXIT
EDIT
I/O SETTINGS
OFF
DI 1
1001 EXT1 COMMANDS
PAR EDIT
DI1
[1]
OFF
CANCEL
SAVE
1001:START/STOP (EI1)
1002:START/STOP (EI1)
___
EXIT
EDIT
I/O SETTINGS
OFF
DI 1
Summary of Contents for ACS320 series
Page 1: ...ABB drives User s manual ACS320 drives 0 5 to 30 hp ...
Page 4: ......
Page 18: ...18 Safety ...
Page 28: ...28 Operation principle and hardware description ...
Page 56: ...56 Electrical installation ...
Page 142: ...142 Program features Connection diagram example ACS320 xx xxxx x ...
Page 282: ...282 Actual signals and parameters ...
Page 358: ...358 Fieldbus control ...
Page 376: ...376 Fault tracing ...
Page 382: ...382 Maintenance and hardware diagnostics ...
Page 407: ...Dimension drawings 407 Frame size R2 NEMA 1 Frame size R2 IP20 NEMA 1 3AUA0000051097 A ...
Page 409: ...Dimension drawings 409 Frame size R3 NEMA 1 Frame size R3 IP20 NEMA 1 3AUA0000051118 A ...
Page 411: ...Dimension drawings 411 Frame size R4 NEMA 1 Frame size R4 IP20 NEMA 1 3AUA0000051133 A ...
Page 412: ...412 Dimension drawings ...
Page 413: ...Index Numerics A B C D E F G H I K L M N O P R S T ...