For the Modbus protocol, drive parameters in group 53 report the parameter mapping
to 4xxxx Registers.
Code
Description
5310
EFB PAR 10
Specifies the parameter mapped to Modbus register 40005.
5311
EFB PAR 11
Specifies the parameter mapped to Modbus register 40006.
5312
EFB PAR 12
Specifies the parameter mapped to Modbus register 40007.
5313
EFB PAR 13
Specifies the parameter mapped to Modbus register 40008.
5314
EFB PAR 14
Specifies the parameter mapped to Modbus register 40009.
5315
EFB PAR 15
Specifies the parameter mapped to Modbus register 40010.
5316
EFB PAR 16
Specifies the parameter mapped to Modbus register 40011.
5317
EFB PAR 17
Specifies the parameter mapped to Modbus register 40012.
5318
Reserved.
5319
EFB PAR 19
Holds a copy (in hex) of the CONTROL WORD, Modbus register 40001.
5320
EFB PAR 20
Holds a copy (in hex) of the STATUS WORD, Modbus register 40004.
5321
MDB DATA IN 1
Specifies the parameter mapped to Modbus register 40013.
5322
MDB DATA IN 2
Specifies the parameter mapped to Modbus register 40014.
5323
MDB DATA OUT 1
Specifies the parameter mapped to Modbus register 40080.
5324
MDB DATA OUT 2
Specifies the parameter mapped to Modbus register 40081.
5325
MDB DATA OUT 3
Specifies the parameter mapped to Modbus register 40082.
5326
MDB DATA OUT 4
Specifies the parameter mapped to Modbus register 40083.
5327
MDB DATA OUT 5
Specifies the parameter mapped to Modbus register 40084.
5328
MDB DATA OUT 6
Specifies the parameter mapped to Modbus register 40085.
5329
MDB DATA OUT 7
Specifies the parameter mapped to Modbus register 40086.
5330
MDB DATA OUT 8
Specifies the parameter mapped to Modbus register 40087.
Summary of Contents for ACS320 series
Page 1: ...ABB drives User s manual ACS320 drives 0 5 to 30 hp ...
Page 4: ......
Page 18: ...18 Safety ...
Page 28: ...28 Operation principle and hardware description ...
Page 56: ...56 Electrical installation ...
Page 142: ...142 Program features Connection diagram example ACS320 xx xxxx x ...
Page 282: ...282 Actual signals and parameters ...
Page 358: ...358 Fieldbus control ...
Page 376: ...376 Fault tracing ...
Page 382: ...382 Maintenance and hardware diagnostics ...
Page 407: ...Dimension drawings 407 Frame size R2 NEMA 1 Frame size R2 IP20 NEMA 1 3AUA0000051097 A ...
Page 409: ...Dimension drawings 409 Frame size R3 NEMA 1 Frame size R3 IP20 NEMA 1 3AUA0000051118 A ...
Page 411: ...Dimension drawings 411 Frame size R4 NEMA 1 Frame size R4 IP20 NEMA 1 3AUA0000051133 A ...
Page 412: ...412 Dimension drawings ...
Page 413: ...Index Numerics A B C D E F G H I K L M N O P R S T ...